Choose this product when
Liquid suspensions, cells, tissue homogenates and compatible dispersions.
Compare eleven XM-T probe sonicators from 150 to 3000 W by processing volume and supplied probe diameter.
Liquid suspensions, cells, tissue homogenates and compatible dispersions.
Probe diameter and immersion conditions determine the usable volume. Power alone does not establish cell-disruption yield or uniformity.
A probe transmits ultrasound into liquid, generating cavitation for cell disruption, dispersion, emulsification and extraction.
Match material and vessel
Use the selected operating setup
Prepare for downstream analysis
Each model retains its own specifications and accessory requirements.
| Model | Nominal power | processing volume | Supplied probe diameter | Details |
|---|---|---|---|---|
| XM-150T | 150 W | 0.1–100 mL | 6 mm | Specifications → |
| XM-250T | 250 W | 0.1–200 mL | 6 mm | Specifications → |
| XM-650T | 650 W | 0.1–500 mL | 6 mm | Specifications → |
| XM-750T | 750 W | 0.1–600 mL | 6 mm | Specifications → |
| XM-900T | 900 W | 0.1–800 mL | 6 mm | Specifications → |
| XM-950T | 950 W | 0.1–900 mL | 6 mm | Specifications → |
| XM-1000T | 1000 W | 0.1–2000 mL | 12 mm | Specifications → |
| XM-1200T | 1200 W | 0.5–2500 mL | 12 mm | Specifications → |
| XM-1500T | 1500 W | 0.5–3000 mL | 12 mm | Specifications → |
| XM-1800T | 1800 W | 0.5–3000 mL | 20 mm | Specifications → |
| XM-3000T | 3000 W | 500–5000 mL | 30 mm | Specifications → |
Check the selected model and container configuration before ordering.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–100 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 150 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–200 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 250 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–500 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 650 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–600 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 750 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–800 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 900 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–900 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 6 mm |
| Dimensions & electrical supply | |
| Nominal power | 950 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.1–2000 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 12 mm |
| Dimensions & electrical supply | |
| Nominal power | 1000 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.5–2500 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 12 mm |
| Dimensions & electrical supply | |
| Nominal power | 1200 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.5–3000 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 12 mm |
| Dimensions & electrical supply | |
| Nominal power | 1500 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 0.5–3000 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 20 mm |
| Dimensions & electrical supply | |
| Nominal power | 1800 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
| Capacity & processing | |
|---|---|
| processing volume | 500–5000 mL |
| Vessels & grinding tools | |
| Supplied probe diameter | 30 mm |
| Dimensions & electrical supply | |
| Nominal power | 3000 W |
The processing range depends on the fitted probe, sample properties, duty cycle and cooling. Match the probe diameter to the sample volume.
Confirm included items and optional accessories in the itemized quotation.
6 mm
6 mm
6 mm
6 mm
6 mm
6 mm
12 mm
12 mm
12 mm
20 mm
30 mm
Liquid suspensions, cells, tissue homogenates and compatible dispersions. Match the preparation method to the material and downstream analysis.
Compare the model-specific specifications below. Include sample amount, vessel size, batch size and temperature requirement in your enquiry.
Plan sample cooling. Match the cooling setup to the sample and operating method.
The selected model, vessels, compatible accessories, optional temperature-control equipment and destination electrical requirements determine the quotation. Request a model-specific configuration and itemized supply list.
Confirm the instrument, accessories and destination requirements in one enquiry.
Request documents for your model and destination market.
Include sample type, amount, batch size, temperature requirements and delivery destination.
Request an itemized supply list with delivery, installation, training and warranty terms.
Request an itemized quote →Discuss the model, operating setup and quotation with the application team.