Choose this product when
Pumpable suspensions, emulsions and compatible biological or formulation liquids.
Compare eight GSL high-pressure homogenizers by design flow, working pressure and minimum processing volume.
Pumpable suspensions, emulsions and compatible biological or formulation liquids.
Micro-volume, pneumatic and larger-flow designs have different process envelopes. Select working pressure rather than equating it with the maximum design pressure.
A high-pressure pump moves a compatible liquid through a narrow homogenizing valve. Pressure release, shear and impact support homogenization, dispersion and cell disruption.
Match material and vessel
Use the selected operating setup
Prepare for downstream analysis
Each model retains its own specifications and accessory requirements.
| Model | Design flow | Working pressure | Minimum processing volume | Details |
|---|---|---|---|---|
| GSL-1.5Pro | 1.5 L/h | 200 MPa | 3 mL | Specifications → |
| GSL-5 | 5–8 L/h | 180 MPa | 25 mL | Specifications → |
| GSL-15 | 12–15 L/h | 180 MPa | 25 mL | Specifications → |
| GSL-15QD | 12–15 L/h | 180 MPa | 25 mL | Specifications → |
| GSL-30 | 25–30 L/h | 150 MPa | 50 mL | Specifications → |
| GSL-40 | 30–40 L/h | 150 MPa | 50 mL | Specifications → |
| GSL-50 | 50–60 L/h | 130 MPa | 120 mL | Specifications → |
| GSL-100 | 80–100 L/h | 130 MPa | 900 mL | Specifications → |
Check the selected model and container configuration before ordering.
| Capacity & processing | |
|---|---|
| Design flow | 1.5 L/h |
| Minimum processing volume | 3 mL |
| Temperature & operation | |
| Working pressure | 200 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 5–8 L/h |
| Minimum processing volume | 25 mL |
| Temperature & operation | |
| Working pressure | 180 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 12–15 L/h |
| Minimum processing volume | 25 mL |
| Temperature & operation | |
| Working pressure | 180 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 12–15 L/h |
| Minimum processing volume | 25 mL |
| Temperature & operation | |
| Working pressure | 180 MPa |
| Other specifications | |
| Drive | Pneumatic |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 25–30 L/h |
| Minimum processing volume | 50 mL |
| Temperature & operation | |
| Working pressure | 150 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 30–40 L/h |
| Minimum processing volume | 50 mL |
| Temperature & operation | |
| Working pressure | 150 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 50–60 L/h |
| Minimum processing volume | 120 mL |
| Temperature & operation | |
| Working pressure | 130 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
| Capacity & processing | |
|---|---|
| Design flow | 80–100 L/h |
| Minimum processing volume | 900 mL |
| Temperature & operation | |
| Working pressure | 130 MPa |
Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.
Pumpable suspensions, emulsions and compatible biological or formulation liquids. Match the preparation method to the material and downstream analysis.
Compare the model-specific specifications below. Include sample amount, vessel size, batch size and temperature requirement in your enquiry.
Configure fluid cooling. Match the cooling setup to the sample and operating method.
The selected model, vessels, compatible accessories, optional temperature-control equipment and destination electrical requirements determine the quotation. Request a model-specific configuration and itemized supply list.
Confirm the instrument, accessories and destination requirements in one enquiry.
Request documents for your model and destination market.
Include sample type, amount, batch size, temperature requirements and delivery destination.
Request an itemized supply list with delivery, installation, training and warranty terms.
Request an itemized quote →Discuss the model, operating setup and quotation with the application team.