8 model configurations
High-Pressure Homogenizer

GSL High-Pressure Homogenizer Series

Compare eight GSL high-pressure homogenizers by design flow, working pressure and minimum processing volume.

Best forPumpable suspensions, emulsions and compatible biological or formulation liquids.
Model range8 configurations
Selection factorsDesign flow / Working pressure / Minimum processing volume
TemperatureConfigure fluid cooling
Selection guide

Is this the right product?

Recommended workflow

Choose this product when

Pumpable suspensions, emulsions and compatible biological or formulation liquids.

Selection boundary

Consider another route when

Micro-volume, pneumatic and larger-flow designs have different process envelopes. Select working pressure rather than equating it with the maximum design pressure.

Applications

Compatible samples

Explore sample applications →

Pumpable suspensions, emulsions and compatible biological or formulation liquids.

Processing method

Working principle

A high-pressure pump moves a compatible liquid through a narrow homogenizing valve. Pressure release, shear and impact support homogenization, dispersion and cell disruption.

  1. Prepare the sample01

    Match material and vessel

  2. Process the sample02

    Use the selected operating setup

  3. Collect the output03

    Prepare for downstream analysis

Model selection

Compare models

Each model retains its own specifications and accessory requirements.

ModelDesign flowWorking pressureMinimum processing volumeDetails
GSL-1.5Pro1.5 L/h200 MPa3 mLSpecifications →
GSL-55–8 L/h180 MPa25 mLSpecifications →
GSL-1512–15 L/h180 MPa25 mLSpecifications →
GSL-15QD12–15 L/h180 MPa25 mLSpecifications →
GSL-3025–30 L/h150 MPa50 mLSpecifications →
GSL-4030–40 L/h150 MPa50 mLSpecifications →
GSL-5050–60 L/h130 MPa120 mLSpecifications →
GSL-10080–100 L/h130 MPa900 mLSpecifications →
Technical specifications

Specifications by model

Check the selected model and container configuration before ordering.

Shanghai Jingxin

GSL-1.5Pro

Capacity & processing
Design flow1.5 L/h
Minimum processing volume3 mL
Temperature & operation
Working pressure200 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-5

Capacity & processing
Design flow5–8 L/h
Minimum processing volume25 mL
Temperature & operation
Working pressure180 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-15

Capacity & processing
Design flow12–15 L/h
Minimum processing volume25 mL
Temperature & operation
Working pressure180 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-15QD

Capacity & processing
Design flow12–15 L/h
Minimum processing volume25 mL
Temperature & operation
Working pressure180 MPa
Other specifications
DrivePneumatic

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-30

Capacity & processing
Design flow25–30 L/h
Minimum processing volume50 mL
Temperature & operation
Working pressure150 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-40

Capacity & processing
Design flow30–40 L/h
Minimum processing volume50 mL
Temperature & operation
Working pressure150 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-50

Capacity & processing
Design flow50–60 L/h
Minimum processing volume120 mL
Temperature & operation
Working pressure130 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Shanghai Jingxin

GSL-100

Capacity & processing
Design flow80–100 L/h
Minimum processing volume900 mL
Temperature & operation
Working pressure130 MPa

Design flow is not a guaranteed throughput for every liquid. Confirm feed viscosity, inlet particle size, valve, pressure and cooling. Pressure in bar is converted to MPa using 10 bar = 1 MPa where applicable.

Common questions

Product FAQ

Which samples can GSL High-Pressure Homogenizer Series process?

Pumpable suspensions, emulsions and compatible biological or formulation liquids. Match the preparation method to the material and downstream analysis.

How do I choose the model and configuration?

Compare the model-specific specifications below. Include sample amount, vessel size, batch size and temperature requirement in your enquiry.

What temperature setup should I use?

Configure fluid cooling. Match the cooling setup to the sample and operating method.

What affects the quotation?

The selected model, vessels, compatible accessories, optional temperature-control equipment and destination electrical requirements determine the quotation. Request a model-specific configuration and itemized supply list.

Plan your purchase

Procurement & support

Confirm the instrument, accessories and destination requirements in one enquiry.

01 / Laboratory setup

Installation requirements

Electrical supply
Confirm voltage, frequency, power, plug and grounding for the selected model.
Bench and access
Check dimensions, equipment weight, lid clearance and maintenance access.
Installation guide →
02 / Product documents

Documentation

Request documents for your model and destination market.

  • Technical datasheet
  • Operating manual
  • Configuration list
Request product documents →
03 / Quotation

Price & supply

Include sample type, amount, batch size, temperature requirements and delivery destination.

Request an itemized supply list with delivery, installation, training and warranty terms.

Request an itemized quote →
Build your configuration

Match the equipment to your sample.

Discuss the model, operating setup and quotation with the application team.

ONLINE ENQUIRY

Let’s discuss your requirements.

Tell us about your samples and the configuration you need.