Model JXFSTPRP-192CL
Cryogenic Grinder

JXFSTPRP-192CL

A high-speed refrigerated grinding homogenizer with vertical oscillation, compressor cooling and container options from microtubes and deep-well plates to 100 mL vessels.

Best forRefrigerated high-throughput workflows requiring a broad vessel range
Maximum format192 × 2 mL deep-well tubes
Temperature range−50 °C to room temperature
Frequency0–70 Hz
Noise level<45 dB
Selection guide

Is this the right product?

Recommended workflow

Choose this product when

You need active refrigeration with high throughput and several large-vessel options

Selection boundary

Consider another route when

Your batch is small or your material needs a dedicated liquid-nitrogen or non-bead grinding mechanism

Confirm the actual number of samples, vessel capacity and adapter before treating the maximum format as the working configuration.

Applications

Compatible samples

Explore sample applications →

Plant tissue

Animal tissue including bone

Fungi and bacteria

Food and pharmaceutical samples

Volatile samples

Plastics, polymers and textiles

Processing method

Working principle

Grinding media process samples inside a refrigerated chamber while the instrument controls the stated temperature range.

  1. Prepare the sample01

    Match material and vessel

  2. Process the sample02

    Use the selected operating setup

  3. Collect the output03

    Prepare for downstream analysis

Technical specifications

Technical specifications

Check the selected model and container configuration before ordering.

Shanghai Jingxin

JXFSTPRP-192CL

Capacity & processing
Feed / final sizeFeed size depends on adapter; final particle size approx. 5 μm
Temperature & operation
Temperature range−50 °C to room temperature
Frequency0–70 Hz
Grinding modesWet, dry and low-temperature grinding
Run programmingThree-stage operation; 1–20 cycles
Cycle interval1–600 s
Run time0–9999 s
Acceleration / deceleration2 s to maximum / minimum speed
SafetyDual electronic locks and lid-open stop function
Vessels & grinding tools
Compatible formats192 × 2 mL deep-well tubes; 96 × 2 mL standard tubes; 48 × 5 mL; 32 × 7–15 mL; 16 × 50 mL; 8 × 100 mL; 2 × 25 mL steel jars; 2 × 50 mL steel jars
Grinding ball diameter0.1–30 mm
Grinding ball materialsStainless steel, chrome steel, zirconia, tungsten carbide and quartz sand
Dimensions & electrical supply
Noise level<45 dB
Vessels & accessories

Vessels & accessories

Confirm included items and optional accessories in the itemized quotation.

Compatible formats

  • 192 × 2 mL deep-well tubes
  • 96 × 2 mL standard tubes
  • 48 × 5 mL
  • 32 × 7–15 mL
  • 16 × 50 mL
  • 8 × 100 mL
  • 2 × 25 mL steel jars
  • 2 × 50 mL steel jars

Grinding ball diameter

0.1–30 mm

Grinding ball materials

Stainless steel, chrome steel, zirconia, tungsten carbide and quartz sand

Application examples

Application cases

Compare the sample, container, conditions and result with your own workflow.

01
Pig liver tissue

Refrigerated preparation of pig-liver tissue

The experiment identifies JXFSTPRP-192CL and combines low-temperature control with high-speed oscillation. The processed liver was reported as a fine homogenate without visible clumps for subsequent analysis.

Read this case →
02
Plastic sample

Low-temperature grinding of a difficult plastic sample

The experiment identifies JXFSTPRP-192CL and uses liquid-nitrogen pre-treatment followed by mechanical grinding to reduce clumping in a tough, heat-sensitive material.

Read this case →
03
Vegetable sample with acetonitrile

Vegetable preparation for pesticide-residue extraction

The experiment used JXFSTPRP-192CL to process vegetable material, grinding media and acetonitrile in sealed tubes before mass-spectrometry analysis. The reported run time was two minutes for the tested setup.

Read this case →
Common questions

Product FAQ

Which samples can JXFSTPRP-192CL process?

Plant tissue Animal tissue including bone Fungi and bacteria Food and pharmaceutical samples Volatile samples Plastics, polymers and textiles Match the preparation method to the material and downstream analysis.

What is the working capacity of JXFSTPRP-192CL?

Up to 192 × 2 mL deep-well tubes, format dependent. Capacity depends on the selected vessel, adapter and actual sample.

What temperature setup should I use?

Adjustable from −50 °C to room temperature. Match the cooling setup to the sample and operating method.

What affects the quotation?

The selected model, vessels, compatible accessories, optional temperature-control equipment and destination electrical requirements determine the quotation. Request a model-specific configuration and itemized supply list.

Plan your purchase

Procurement & support

Confirm the instrument, accessories and destination requirements in one enquiry.

01 / Laboratory setup

Installation requirements

Electrical supply
Confirm voltage, frequency, power, plug and grounding for the selected model.
Bench and access
Check dimensions, equipment weight, lid clearance and maintenance access.
Cooling and handling
Plan ventilation, protective equipment and coolant handling for the selected cooling method.
Installation guide →
02 / Product documents

Documentation

Request documents for your model and destination market.

  • Technical datasheet
  • Operating manual
  • Configuration list
Request product documents →
03 / Quotation

Price & supply

Include sample type, amount, batch size, temperature requirements and delivery destination.

Request an itemized supply list with delivery, installation, training and warranty terms.

Request an itemized quote →
Build your configuration

Match the equipment to your sample.

Discuss the model, operating setup and quotation with the application team.

ONLINE ENQUIRY

Let’s discuss your requirements.

Tell us about your samples and the configuration you need.