Model JXFSTPRP-576
High-Throughput Tissue Grinder

JXFSTPRP-576

An ultra-high-throughput tissue grinder for up to 576 samples, with nine 96-well plate positions and alternative tube or grinding-jar configurations.

Best forVery large batches and plate-based sample-preparation workflows
Maximum throughput576 samples
Plate capacity9 × 96-well plates
Frequency0–50 Hz
Rated power1100 W
Selection guide

Is this the right product?

Recommended workflow

Choose this product when

You need several hundred samples or multiple 96-well plates processed as one batch

Selection boundary

Consider another route when

Your workload is below plate scale or you require active refrigerated chamber control as standard

Confirm plate or tube configuration, balance requirements, daily batch count and downstream extraction workflow.

Applications

Compatible samples

Explore sample applications →

Plant and animal tissue

Microorganisms

Soil and minerals

Pharmaceutical samples

Polymers and materials

Processing method

Working principle

Parallel tube, plate or jar formats use oscillating grinding media for batch sample preparation.

  1. Prepare the sample01

    Match material and vessel

  2. Process the sample02

    Use the selected operating setup

  3. Collect the output03

    Prepare for downstream analysis

Technical specifications

Technical specifications

Check the selected model and container configuration before ordering.

Shanghai Jingxin

JXFSTPRP-576

Capacity & processing
Maximum throughput576 samples
Final particle sizeApprox. 5 μm
Temperature & operation
Frequency0–50 Hz
Run time0–9999 s
Grinding modesWet, dry and low-temperature grinding
Safety / clampingAutomatic center-positioning clamp
Vessels & grinding tools
Compatible formats9 × 96-well deep-well plates; 90 × 5 mL tubes; 72 × 7–15 mL tubes; 9 × 50 mL steel jars; 30 × 50 mL wear-resistant tubes
Grinding ball diameter0.1–30 mm
Grinding ball materialsStainless steel, chrome steel, zirconia, tungsten carbide and quartz sand
Dimensions & electrical supply
Rated power1100 W
Power supply220 V single-phase AC, <10 A
DimensionsApprox. 580 × 470 × 700 mm
Noise level<55 dB
Other specifications
Grinding platforms30
Clamp travel38 mm vertical
Vessels & accessories

Vessels & accessories

Confirm included items and optional accessories in the itemized quotation.

Compatible formats

  • 9 × 96-well deep-well plates
  • 90 × 5 mL tubes
  • 72 × 7–15 mL tubes
  • 9 × 50 mL steel jars
  • 30 × 50 mL wear-resistant tubes

Grinding ball diameter

0.1–30 mm

Grinding ball materials

Stainless steel, chrome steel, zirconia, tungsten carbide and quartz sand

Application examples

Application cases

Compare the sample, container, conditions and result with your own workflow.

01
Dried rice leaves · 96-well deep-well plate

High-throughput preparation of rice leaves

The experiment explicitly used JXFSTPRP-576 with steel balls in a 96-well deep-well plate to prepare rice leaves for a transgenic-testing workflow.

Read this case →
02
Dried wheat · 50 mL PTFE jar

Dry grinding of wheat for analytical preparation

The experiment identifies JXFSTPRP-576 and records dry grinding at 45 Hz for 60 seconds, repeated twice, using a 50 mL PTFE jar.

Read this case →
03
Corn kernels

Corn-kernel preparation for nitrogen analysis

The experiment identifies JXFSTPRP-576 and documents corn-kernel grinding before nitrogen-content measurement, using multiple groups to compare the preparation result.

Read this case →
Common questions

Product FAQ

Which samples can JXFSTPRP-576 process?

Plant and animal tissue Microorganisms Soil and minerals Pharmaceutical samples Polymers and materials Match the preparation method to the material and downstream analysis.

What is the working capacity of JXFSTPRP-576?

Up to 576 samples. Capacity depends on the selected vessel, adapter and actual sample.

What temperature setup should I use?

Wet, dry and low-temperature workflows; cooling as an upgrade. Match the cooling setup to the sample and operating method.

What affects the quotation?

The selected model, vessels, compatible accessories, optional temperature-control equipment and destination electrical requirements determine the quotation. Request a model-specific configuration and itemized supply list.

Plan your purchase

Procurement & support

Confirm the instrument, accessories and destination requirements in one enquiry.

01 / Laboratory setup

Installation requirements

Electrical supply
Confirm voltage, frequency, power, plug and grounding for the selected model.
Bench and access
Check dimensions, equipment weight, lid clearance and maintenance access.
Cooling and handling
Plan ventilation, protective equipment and coolant handling for the selected cooling method.
Installation guide →
02 / Product documents

Documentation

Request documents for your model and destination market.

  • Technical datasheet
  • Operating manual
  • Configuration list
Request product documents →
03 / Quotation

Price & supply

Include sample type, amount, batch size, temperature requirements and delivery destination.

Request an itemized supply list with delivery, installation, training and warranty terms.

Request an itemized quote →
Build your configuration

Match the equipment to your sample.

Discuss the model, operating setup and quotation with the application team.

ONLINE ENQUIRY

Let’s discuss your requirements.

Tell us about your samples and the configuration you need.